MP503 Air-Quality Gas Sensor

 

MP135/MP503 air quality gas sensor

MP135/MP503 air quality gas sensor using multilayer thick film manufacturing process, in the micro AI203 ceramic substrate on both sides of the heater and metal oxide semiconductor gas sensing layer, encapsulated in the metal shell. The conductivity of the sensor changes when there is a detected gas in the ambient air. The higher the concentration of the gas, the higher the conductivity of the sensor. This conductivity change can be converted into an output signal corresponding to the gas concentration by a simple circuit.

This product is sensitive to alcohol, smoke, isobutane, formaldehyde; It has the advantages of fast response recovery, low power consumption, simple detection circuit, good stability, long life, etc.
Scope of application:
Used for home environment and office harmful gas detection, automatic exhaust device, air freshener, etc.

Model MP503
Sensor Type Semiconductor flat surfaced sensor
Standard Encapsulation Metal Cap
Detection Gas Alcohol, Smoke
Detection range 10~1000ppm(Alcohol)
Standard circuit Loop voltage VC ≤24V DC
Heating voltage VH 5.0V±0.1V AC or DC
Load resistance RL Adjustable
sensor features in standard test condition Heating resistance RH 95Ω±10Ω(Room Tem.)
Heating consumption PH ≤300mW
Surface resistance RS 1KΩ~30KΩ(in 50ppm Alcohol)
Sensitivity S Rs(in air)/Rs(in 50ppm Alcohol)≥5
Concentration slope α ≤0.6(R100ppm/R30ppm alcohol)
Standard condition of test Temperature, humidity 20?±2?;65%±5%RH
Standard test circuit VC:5.0V±0.1V; VH :5.0V±0.1V
Warm-up time More than 48 hours